Technical Reference for ZyXEL omni.net series
B-9
All the Following Commands Require a 'AT' Prefix
S Com. bit dec hex Function and description +Def./Ref.
S29= 0-39 0-39
Set default dial phone number pointer, use 'AT&Zn=s' to
store phone numbers.
+000 *D
S31= 0-25
5
0-FF Holds the ASCII decimal value of the XON. +017
S32= 0-25
5
0-FF Holds the ASCII decimal value of the XOFF. +019
S35= bit dec hex Bit mapped register
6 64 30 Enable password protection to profile saving, when
<AT&Wn> is issued, and the 'n' profile in the memory has
this bit on, supervisory password will be requested.
&Wn
7 128 60 Enable extended numerical result codes from 50-71 when
an error corrected connection is made. Use with 'ATV0' (see
result code table).
V0
S23b6
S36= bit dec hex Bit mapped register +000
5-7 Security function control register
0 (*) 0 Disable security function. *G0
32 20 Enable type 1 security, with password check (Proprietary). *G1
64 40 Enable type 1 security, with password check and callback
(Proprietary).
*G2
96 60 Enable type 2 security, with password check. *G3
128 80 Enable type 2 security, with password check and callback. *G4
160 A0 Enable type 2 security, with password check and callback.
Remote site enters the callback number.
*G5
S38= bit dec hex Bit mapped register +000
0 1 1 Repeatedly dialing default number.
*Dn, S29
1-2 Reserved.
2 4 4 Key for ATSWR, ATHWR.
3 8 8 DCD on/off sequence follows UNIX standard, DCD high
before connect message is sent, DCD off after last DCE
response is sent.
&C1 S21b4
S40= bit dec hex Bit mapped register +000
1 2 2 No result code displayed in answer mode. Q2